Ceiling Cassette Air Conditioning Plymouth
Ceiling cassette air conditioning in Plymouth, designed, installed and wired by HPE Airflow SW Ltd. A cassette sits flush into the ceiling and pushes air out in four directions, which makes it the natural choice for offices, shops, treatment rooms and large open plan spaces.
We are F-Gas certified and an NICEIC Approved Contractor, so the refrigerant work and the electrical connection are both ours.
What a cassette does differently
A wall-mounted unit throws air from one side of the room. A cassette sits in the middle of the ceiling and throws it out on all four sides at once. In a wide or square room that difference is significant, because a single wall unit has to work harder to reach the far corner and you get warm and cool patches as a result.
The visible part is just a flat grille, usually 600mm square, sitting level with the ceiling tiles. Everything else, the coil, the fan and the pipework, is hidden in the void above. Nothing protrudes into the room.
That combination, even air distribution and almost no visual presence, is why nearly every modern office and retail unit uses them. Once you notice them you see them everywhere; before that, most people never spot them at all.
Open plan offices and zoning
Most cassette work we do is commercial, and the recurring problem in an open plan office is not capacity. It is that different parts of the same room need different things at the same time.
A floor with glazing along one elevation will have a south facing side gaining heat all afternoon and a north facing side that never does. Treat it as one space with one setpoint and half the office is too warm while the other half is reaching for a cardigan. This is the single most common complaint we are called in to resolve, and it is a design problem rather than an equipment fault.
The answer is multiple units on separate controls rather than one large unit in the middle. Each cassette conditions its own area and responds to its own conditions, so the sunny side works harder without overcooling everybody else. It also gives you resilience: if one unit fails, the office is uncomfortable rather than unusable.
Heat load from equipment is the other factor people underestimate. A room full of monitors, a comms cabinet in the corner and forty people generates a substantial constant load that has nothing to do with the weather, which is why offices frequently need cooling in months when nobody would expect it.
We survey on the actual occupancy and equipment rather than floor area alone, and we would rather tell you at that stage that you need three units instead of two than have you unhappy in July.
What the ceiling needs to allow
The one requirement is a void above the ceiling deep enough to take the body of the unit. A suspended ceiling in a commercial unit almost always has it. A domestic ceiling usually does not, which is why cassettes are far more common in commercial settings.
Where the void is too shallow, there are slimline models, and sometimes a small section of ceiling can be dropped. But if none of that works, a ducted system or a wall-mounted unit is the honest recommendation. We will measure the void at survey and tell you which of those you are actually choosing between, rather than quoting for something that will not fit.
Condensate is worth mentioning. A cassette sits above a ceiling, which means a leak shows up on someone’s desk. Cassettes include a condensate pump, and the drain installation is one of the places where care matters more than speed.
Where we fit them
Offices. Even distribution matters when people sit in fixed positions all day. A wall unit blowing at one desk and not reaching another causes more complaints than no air conditioning at all.
Shops and showrooms. Discreet, quiet, and free of any box on the wall competing with the display.
Treatment rooms, salons and clinics. Air movement without a draught blowing directly at a client on a couch.
Restaurants and cafes. Kitchens push heat into the dining space and door traffic is constant. Multiple cassettes on a shared system let you treat different zones properly.
Large domestic open plan rooms. Where there is a void to work with, a cassette handles a big kitchen-diner far better than one wall unit at one end.
See also commercial air conditioning installation.
Heating too, and zoning
Cassettes reverse like any other air conditioning unit, so they heat as well as cool. For commercial premises that is often the deciding argument, because one system replaces both the cooling problem and an ageing heating system, and it runs on electricity rather than gas.
Several cassettes can run from one outdoor condenser with each zone independently controlled, so a south-facing meeting room and a north-facing back office are not forced to share a setting. Rooms that are not in use can simply be switched off.
Equipment, compliance and servicing
We install Daikin as our primary range, with Daikin certification CI35, alongside Mitsubishi, Toshiba and Hitachi.
Commercial systems above certain refrigerant charges must be leak tested at set intervals with records kept, and only F-Gas certified engineers may do that work. Our F-Gas number is 2000776.
Cassettes run long hours in commercial use and need planned servicing to hold their efficiency. We also handle repairs on systems other firms installed.
Can a ceiling cassette go in any room?
No. It needs a suspended ceiling with enough clear depth above it, typically around three hundred millimetres although it varies by model. In a shallow void or a solid ceiling, a ducted or wall mounted unit is the honest answer instead.
What else has to be in the ceiling void?
Nothing in the way. Older commercial buildings around Plymouth often have lighting, cable trays, sprinkler pipework and ventilation ducting occupying exactly the space the cassette needs. We check that at the survey rather than discovering it on installation day.
How is the condensate dealt with at ceiling level?
A small integral pump lifts it to a suitable drain. It has to be routed properly, because a condensate run that relies on optimism rather than a fall will eventually show up as a stain on the ceiling tiles.
Why choose a cassette over wall units?
Four way discharge gives even distribution without the strong directional draught a wall unit produces. In a square open plan office one well placed cassette often does the work of two wall units, and it is far less conspicuous because only the grille shows.
Do they heat as well?
Yes, they reverse like any other air conditioning unit, so the same equipment heats the space in winter. For commercial premises that is often the strongest part of the case.
What are the compliance obligations?
Commercial systems above a certain refrigerant charge must be leak checked at set intervals with records kept. We are F-Gas certified, register number 2000776, and we carry out the checks and keep the records as part of a maintenance agreement.
Arrange a survey
Call 07789 373208 or send an enquiry. We will check the ceiling void, work out the real heat load for the space and tell you what fits.