Split Air Conditioning Plymouth

Split air conditioning in Plymouth, supplied, installed and wired by HPE Airflow SW Ltd. A split system is the standard arrangement for homes and smaller commercial premises, and it is the type we fit most often.

We are F-Gas certified for the refrigerant work and an NICEIC Approved Contractor for the electrical side, so the whole installation is done by one team.

What a split system actually is

A split system is called that because it comes in two parts. There is an indoor unit in the room being treated, and an outdoor condenser mounted on a wall, a flat roof or a ground frame. Refrigerant pipework and a control cable run between the two, usually through a small hole in the wall.

The heat is not destroyed, it is moved. In summer the system takes heat out of the room and dumps it outside. In winter it does the opposite, taking warmth from the outside air and bringing it in, which is why a modern split system is a heater as much as a cooler. It is the same principle as a heat pump, because that is essentially what it is.

The reason splits dominate is that they are efficient, quiet and relatively simple to install. Nothing needs ripping out, no ductwork is required, and a single room can be done in a day.

Where the outdoor unit goes

The decision people give least thought to, and regret most often, is where the outdoor condenser ends up.

It needs air. A condenser rejects heat to the outside, and one boxed into a narrow passage, tucked behind a fence panel or shut inside a decorative cabinet with no ventilation will recirculate its own hot air, run harder than it needs to and cost more to operate. Manufacturers specify minimum clearances and they are not decorative.

It makes noise. Not a great deal, and modern units are quiet, but it is continuous. Under your own bedroom window is a mistake you make once. Between two terraced houses, where sound bounces off both walls, is a mistake your neighbour makes you regret. In the tighter Victorian terraces around Plymouth this is the constraint that most often decides the layout.

It needs to be reachable. Filters, coils and the condensate need annual attention, and a unit mounted high on a wall over a conservatory roof means a scaffold tower every time it is serviced.

And near the coast it needs consideration for salt. Outdoor coils corrode noticeably faster in Looe or the South Hams than three miles inland, so position matters, and coated coils are worth specifying.

We settle all of this at the survey rather than on installation day.

Planning for rooms you have not done yet

The most common regret with split systems is not the unit chosen. It is doing one room, being pleased with it, and then discovering that adding the second room means a second outdoor unit on the wall.

A multi split runs several indoor units from one outdoor condenser, but the condenser has to be specified with that in mind. Fit a single split sized precisely for one bedroom and there is no spare capacity, so the only way to add the study next year is another complete system, another condenser and another set of holes in the wall.

Fitting a slightly larger outdoor unit at the start, with capacity for indoor units you have not bought yet, costs comparatively little on day one. The pipework for future rooms can also be run and capped while walls or ceilings are open, which is by far the cheapest moment to do it.

So the question we ask at survey is not just which room is uncomfortable now. It is which rooms you can imagine wanting done in the next five years, and whether any building work is planned that would make running pipework easy.

If the honest answer is one bedroom and never anything else, a single split is the right choice and we will fit that. But it is worth thinking about for two minutes before deciding, because retro fitting capacity is the expensive way round.

Single split or multi split

A single split pairs one indoor unit with one outdoor unit. It is the cheapest way to treat one room and the right answer where only the bedroom, the loft conversion or the office genuinely needs it.

A multi split runs several indoor units from one outdoor condenser, each controlled independently. It costs more up front but only one outdoor unit is needed, which matters if wall space is limited or if you do not want three condensers on the back of the house. Each room can be set to its own temperature, and rooms not in use can simply be off.

The decision usually comes down to how many rooms you expect to treat eventually rather than immediately. It is worth sizing the outdoor unit for the rooms you might add later, because retro-fitting capacity is more expensive than allowing for it at the start. We will raise that at the survey.

Choosing the indoor unit

The outdoor half is largely fixed. The indoor half is where the real choice sits.

  • Wall mounted is the most common and most affordable, fitted high on the wall.
  • Ceiling cassettes sit flush in a suspended ceiling and throw air in four directions, which suits square or open plan rooms.
  • Ducted units hide above the ceiling with only grilles on show, for period rooms and interiors where visible hardware is unacceptable.
  • Floor mounted units work where there is no suitable high wall space, often under a window in a room with sloping ceilings.

Getting the installation right

Most split system problems are installation problems, not equipment problems. Pipework runs that are too long or badly insulated lose efficiency. A condensate drain that relies on optimism rather than a fall will eventually leak down a wall. An outdoor unit crammed into a corner with no airflow around it will run hot and work harder than it needs to.

Noise is the other one people regret. An outdoor condenser positioned under a bedroom window, or in a narrow passage between two houses where sound bounces, causes arguments with neighbours that are difficult to fix afterwards. We consider that at survey stage rather than on the day.

Refrigerant handling is legally restricted to F-Gas certified engineers. Our number is 2000776. A system charged badly will underperform from day one and no amount of adjusting the remote will fix it.

Equipment we fit

Daikin is our main range and Alan is a Daikin certified installer, number CI35. We also install and service Mitsubishi, Toshiba and Hitachi equipment.

We are happy to explain the difference between a budget unit and a good one, because on split systems it shows up in noise levels and in how the system behaves at the extremes rather than in the headline output figure.

Servicing

Splits need annual attention: filters cleaned, condensate drain checked, refrigerant charge verified, coils cleaned. We offer servicing and repair whether or not we installed the system.

For properties near the sea, at Looe or around Kingsbridge and the South Hams, we shorten the interval because salt air attacks outdoor coils.

A single split pairs one indoor unit with one outdoor unit, and is the cheapest way to treat one room. A multi split runs several indoor units from one outdoor condenser, each controlled independently. Multi costs more up front but avoids having three condensers on the back of the house.

A typical single room domestic installation runs between £800 and £1,200, depending on the unit, the room and how far the pipework has to travel. Multi split and commercial systems are quoted after a free survey.

Somewhere with airflow around it, away from bedroom windows, and not in a narrow passage between two houses where sound reflects. We decide this at the survey rather than on installation day, because the position is the thing people most often regret.

Yes, if the outdoor unit was sized for it. Retro-fitting capacity is more expensive than allowing for it at the start, so we will ask at the survey how many rooms you might eventually want, not just the one you are asking about today.

Yes. It is essentially a heat pump, so it heats efficiently in winter as well as cooling in summer. That is why a unit bought for one hot fortnight often ends up heating a home office for half the year.

We do. F-Gas certified for the refrigerant, register number 2000776, and an NICEIC Approved Contractor for the wiring, number D602867. One team, one visit, no second contractor to arrange.

Book a free survey

Call 07789 373208 or send an enquiry. We cover Plymouth, Plympton, Plymstock, Ivybridge and Tavistock.

Hours: Monday to Friday 7am to 8pm, Saturday 8am to 4pm, Sunday 9am to 1pm. Email info@airflowsouthwest.co.uk